CT manufacturing constraint

i came across in once of the catalogues tat the CT with a ratio of thermal withstand current to the rated current of CT greater than 500 cud not be manufactured.. does any one knw wat mite be t reason for it ? thanks in advance ..

SA 213 TP 304L

If we use SA 213 TP-304 L grade tube up to 520 Degree C Temp for 20 Minute then what type of degradation can take place.

We have one electrical heater having a shell of SA213 TP-304L .That is design for 300 Degree C ONLY but due to some reason electrical heater did not cut off and temp of she

2001chevy cavalier wont start

I have had repeated trouble with this car.It has had a no start condition three times in five months.I have checked for air,fuel,and fire.The plugs smell of gas,but the ignition control module and coils check out o.k. I am stumped as to what to do any help would be great

Member

Happy 2k10 all off you.

Could someone there advice: I have just rewired a residential house and inorder to control overcurrent and earth leakages, I installed all the circuits with Rcbos. And because the type of earthing used is a TT system, I have installed a RCD and MCB at the incoming mains.

Oil products removal before reparing

Dear All

As you know in petrochemical and refinery industry are used a lot of heat exchangers. Sometimes due tube leaks these exchangers need to be removed from the process unit to be repaired. Usual procedure say to be purged with steam before to start any mecanical activity for any exchanger

Lean Green War Machine

With oil becoming more cost prohibitive everyday, all branches of the U.S. Military have been ordered to go green. Geothermal energy is the power of choice as evidenced by the China Lake, 270-megawatt geothermal power plant in California. The site, and others, will produce 600 MW annually according

Voltage drop

Antorone

Maybe the answer could be a small Renewable Thermal Wind power systems over your staruture, this is a cone shape structure and can be made rather inexpansicvely than most think. Use the structures roof as a wind chamber that is with a covered area under it for outside storage with out

chlorine injection

hi every body

i want to ask about the most recent technology for chlorine and cauastic soda injection in water projects ( pumping stations ) . we use ( prums + evapourators + regulators + chlorinators + injectors ) ( metering pumps + dosing pumps ) any other methods

thank you

Bubbles in Paint on DM Storage Tank Wall

We have 510 M3 storage tank of DM Water which was painted 9 Years before i.e Year 2000 with Epoxy paint. In 2005 we inspected the tank, but bubbles were not observed. We inspected DM storage tank once again yesterday and we found moce concentated small bubbles in paint in about 3 meter height from t