Boiler Feedwater – Acceptable TDS

On this platform, I have a Scotch 3 pass wet back boiler, Mod: Series 400. It is used for generating steam for cleaning and heating applications. I have read through the manufacturer's nomenclature and can find nothing about the quantities of total dissolved solids (tds) that is acceptable in the fe

Syncrocheck Relay Malfunction

what will happen in details if two un equal voltage for power transformer connected in parallel due to problem in syncrocheck relay?

where the first transformer voltage was 6.3 KV and the another was 7.3 KV

and the both transformers were connected in parallel.

initially ik

Voltage Transformers

dear sir,

i would like to ask a question which why can not use the fuse on the secondary of the voltage transformer on the generator grounding transformer?

i have gen. grounding transformer 14.2/0.24 KV in addition to 0.6 ohm resistance for grounding ,we used voltage transformer 24

Piping Questions

1- in the o-let branch connection, What is the size (with tolerance) of the opening in run pipe?

2- the attachement between the olet and the run pipe shall be full penetration grove weld?

3- deose the "full penetration groove weld" mean "complete fusion of the run pipe opening at

Light The Halls With LEDs

More than twice as efficient as compact fluorescent lights (CFLs), light emitting diodes (LEDs) are steadily creating a new standard for green lighting. Once limited to traffic lights, Christmas lights, and scoreboards, LEDs are quickly becoming an attractive alternative to traditional lightin

Why we keep animals in captivity?

The tragedy, last week, of a killer whale dragging his trainer underwater to his dead at the SeaWorld Orlando animal "torture house" should not be a surprise to any moral and intelligent person. The tragedy – not the first one of this kind – should be an awakening to all of us who app

Studies Supporting HHO Boosting

Doug RH has claimed that a Livermore study demonstrates that HHO boosters work as claimed, showing improvements of as much as 65%, He further claims that my understanding of current HHO research is hopelessly rooted in century-old thinking. Maybes he's right. Thus this thread.

Having actually

4-hp Compressor

Please help me ,to make it run.......

I have single ohase 7kw genset, trying to start 4 hp single phase air compressor,when the swith on gen set overload and stop ....

thanx

Piping Jobs

hello friends..m in final year (last semister)of chemical engg & have first class in aggregate..m also doing diploma course in "piping & materials".

I m looking 4 a job in pipng design field..cud any1 suggest me 4 d same..!!!!

LT Switchgear Upgrades

Dear all,

we have 5.5KW LCP module in LT mcc but we have the motor of capacity 22kw, 415v, 3ph, full load current: 39A. No other spare modules are available. now i want upgrade the 5.5kw module to 22kw module. what are the things to be considered for conversion. I had doubt in dimensi