Dear All,
We are using aluminium piping in our spice conveying system.
Why not Stainless steel or flexible Piping?
Regards.
This Where Those Homework Questions are Coming From
Saw this article in the ninemsm website.
It explains why we get so many homework questions.
http://news.ninemsn.com.au/article.aspx?id=8140141
Ok so where is our cut?
Load Analysis Layout
I have a 277/480 service with a 120/208 load in a restaraunt I am building. The a/c's (3) and vent hood are 480v. Layin lighting 277v. All other load will be gas or 120v. I understand the calculations fine, but I am not sure how to layout the written load analysis, because of the dual voltages. Can
Workshop
pls update information about workshops and conference held in any other colleges in tamilnadu belongs to instrumentation
Star Delta Motor Running Trouble
when the 55 kw motor converts from star to delta it trips. But the contactor is latched on. so we started the motor in delta. it runs. when we reverted back to normal star delta fashion the same thing happened. when the timer and OLR were changed, the star contactor was on, but not the main contacto
Noise Reduction for AV installation
An AV consultant on one of our projects has requested a separete isolation transformer to power all his rack and room mounted equipment. This is a 8 story building and the equipment is scatttered trhoughout the facilty. We are using a 600 Volt distribution system that uses ZigZag transfomers at each
Lifespan of Pressure Parts
Dear all,
I would like to know the standard that includes lifespan requirements for pressure parts of big coal fired power plant (such as main steam pipe, valve, steam drum, etc.). Please help me soon!
Sizing of Drop Out Fuse
I have a 100kVA 11kV/0.4kV Dyn11 type transformer. I want to connect a 20kW HydroPower plant to this 11 kV grid with this transformer. So, how can I calculate the size of Drop out fuse to connect HV side transformer to 11 kV grid? Or shoud I use MCCB??
3P 115A Contactor Coil Power Consumption
I am using 460/120V AC 150VA stepdown transformer for controling the circuit.i want to know about what is the power consumption of 120 vac coil to start the motor.
thanks
suthakaran
Thermal – Balance Leak Off Line
what is the function of a balance leak off line in a feed pump of a boiler ?
Browning Bar Serial Number Date of Mfg.
Is there a list of browning bar serial numbers with dates of mfg. available?
Thanks - Bob
The Recipe for CEO Success
What are the key characteristics of a successful CEO heading an innovative company? Machine Design editor Leland Teschler describes wish list, which includes overconfidence (characterized by how CEOs manage their stock options), and an "unwavering resolve and workmanlike diligence" for getting work
Asking for Formula and Working Details as a Beginner Electrical Engineer
A current of 50A is carried by two cables in parallel. One cable has a resistance of 0.15ohms-and carries 20A. What is the resistance of the other cable?
Too Old to Hire?
Despite laws against discrimination on the basis of age, older workers, those 50 plus, say they have the biggest disadvantage when seeking a job. In fact, employment counselors suggest that age may be the most common form of workplace discrimination. Why do think employers are so reluctant to hire o
More Transparent OLEDs For Phones
See-through OLED panels can be made by either keeping the emitter and driver layers very thin, or by leaving areas empty except for a see-through substrate. A 2-inch 320 x 240 (QVGA) OLED panel, deposited on glass, let more than 50% of the light through. They seem destined for phones — but why
Motor Connection – Ladder Diagram of Star Delta
hi every one please tell me about ladder diagram of star delta. regards
Condensing Turbine Won't Rotate After 2 Days Shutdown
Our condensing 5,5 MW steam turbine has been operating
for 4 years without problems.By start after short 2 days shutdown we found out barring gear broken.After repair we tryed to start turbine again but is´t impossible to spinn the turbine.Turbine was stopped right regularly before shutdown.
Motor Theory
hi can anyone give me a help with this question please?
i need to find starting voltage of the motor, the percentage of normal torque when the motor is started the motor start current and supply current.
i thnk the point of the exercise is to bring home the point that that trfx for st