Vitamin B7 monitoring device for food and clinical samples analyses – Phys.Org

Posted: July 13, 2017 at 7:08 am

July 13, 2017 Development of an electrochemical immunosensor for direct detection of vitamin B7 in real samples. Credit: Dr. Khor Sook Mei

Direct detection of vitamin B7 in real sample is possible using the developed immunosensor without the need of sample pre-treatment. The immunosensor not only leads to shorter analysis time but also is a user-friendly approach to the end user.

Vitamin B7, also known as biotin, is one of the essential nutrients in human body. It is important for cell growth, body metabolism, healthy skin, hair and nail strengthening as well as for blood sugar balancing. Besides that, adequate vitamin B7 consumption is very important for normal fetal development, as marginal deficiency of vitamin B7 during pregnancy may lead to fetal malformation. Symptoms of vitamin B7 deficiency include scaly dermatitis, conjunctivitis, hair loss, loss of appetite, hallucination, depression and developmental delay. Hence, adequate intake of vitamin B7 is necessary. The daily intake of vitamin B7 for infants (0-5 months), children, adults (> 18-year-old) and pregnant women were recommended to be 5 g, ~20 g, 30 g and 30 g, respectively. Natural sources for vitamin B7 include raw egg yolk, nuts, liver, cauliflower and cereal. Vitamin B7 is also available as supplements in effervescent tablets or capsules. Therefore, monitoring of the content of vitamin B7 in human body (especially pregnant women) and quantification of vitamin B7 in foods and supplement products are important.

Detection of vitamin B7 using the developed immunosensor is based on the specific interactions between vitamin B7 and its antibodies on the immunosensor interface, leading to the change in electrochemical property of the immunosensor interface. The change in electrochemical property of immunosensor interface is varying with the concentration of vitamin B7 in tested actual sample. Due to the anti-fouling capability resulted from the zwitterionic property of the modified immunosensor interface, the unwanted interferences (especially from non-specific proteins adsorption) in real sample can be prevented from accessing the immunosensor interface by a water hydration layer, thus the generated detection signal will be accurate (neither false positive nor false negative reading was observed). In addition, results obtained for the stability, selectivity, reproducibility, and intra-day/inter-day precision of the electrochemical immunosensor were proven to be as good as compared to other reported studies.

Furthermore, quantification of the concentration of vitamin B7 in real samples such as infant formulas, supplements and human serum using the developed immunosensor was validated by standard HPLC method with a photodiode array detector. Unlike using HPLC technique, only simple dilution step is needed for the vitamin B7 detection in real sample using the developed immunosensor, thereby it is much simpler to be used and able to produce a sensitive and specific detection signal in about 15 minutes. To conclude, the newly developed electrochemical immunosensor is reliable, stable, reproducible, precise and reliable for the quantification of vitamin B7 in real samples.

Explore further: Fast detection of Dengue virus with new diagnostic

More information: Mai Mai Khoo et al. Impedimetric biotinImmunosensor with excellent analytical performance for real sample analysis, Journal of Electroanalytical Chemistry (2017). DOI: 10.1016/j.jelechem.2017.05.048

Provided by: University of Malaya

Fast detection for Dengue virus is possible based on an innovative label free immunosensor. The novel immunosensor with antibody-nanoparticle hybrid design offers high selectivity and sensitivity for Dengue virus NS1 biomarker ...

Those with a genetic intolerance to lactose may suffer from a vitamin D deficiency. That's according to a recent study conducted at the University of Toronto and published in the Journal of Nutrition.

(HealthDay)For patients with type 2 diabetes (T2D) and vitamin D deficiency, vitamin D supplementation has no impact on insulin sensitivity or secretion, according to a study published online May 3 in Diabetes Care.

A new study, led by Prof. Jaesung Jang at Ulsan National Institute of Science and Technology (UNIST), South Korea, has developed a new sensor for early detection of heart attack in humans.

(HealthDay)Vitamin D deficiency is associated with dry eye and impaired tear function, according to a study published in the January issue of the International Journal of Rheumatic Diseases.

Vitamin D deficiency may increase the risk of chronic headache, according to a new study from the University of Eastern Finland. The findings were published in Scientific Reports.

When it comes to efficiency, sometimes it helps to look to Mother Nature for advice - even in technology as advanced as printable, flexible electronics.

Charged surfaces submerged in an electrolyte solution can sometimes become oppositely charged. This nonintuitive phenomenon, known as charge inversion, happens when excess counter ions adsorb, or adhere, to the surface. It ...

A Rice University laboratory that specializes in synthesizing reagents and intermediate molecules for the design and manufacture of drugs and other fine chemicals has delivered on a promise to generalize the synthesis of ...

A team of scientists has used microwaves to unravel the exact structure of a tiny molecular motor. The nano-machine consists of just a single molecule, made up of 27 carbon and 20 hydrogen atoms (C27H20). Like a macroscopic ...

Scientists at the University of Sheffield have published new research illuminating how energy is transferred in molecules - something that could influence new molecular technologies for the future.

Scientists at the University of North Carolina at Chapel Hill and Duke University have created the first general-purpose method for using machine learning to predict the properties of new metals, ceramics and other crystalline ...

Please sign in to add a comment. Registration is free, and takes less than a minute. Read more

Read more from the original source:

Vitamin B7 monitoring device for food and clinical samples analyses - Phys.Org

Related Posts